Wired Flush-mounting Basic Discussion System with Voting TL-5600(讨论表决终端 )
Discussion Unit TL-VDQ5600/ TL-VXQ5600
Delegate discussion unit (TL-VDQ5600) allows the delegate to talk, request to talk, and register attendance. 1 to 4 delegate microphones can be active simultaneously. Built-in loudspeaker automatically mutes when the microphone is turned on. Chairman discussion unit (TL-VXQ5600) has the additional priority button to override all active delegate units to control the conference. Multiple chairman and vice-chairman discussion units can be used in one system, and can be active at any time regardless of preset delegate microphone limit.
Main Features
◆ Blue LED indicator for chairman or VIP
Basic Functions
Technical Specifications
Installation |
flush mounting |
Frequency response |
30Hz~20KHz |
Max SPL |
125dB (THD<3%) |
Dynamic range |
85dB |
Sensitivity |
-46dB±4dB |
THD |
THD<0.3% |
SNR |
≥95dB |
Power |
24V |
VOX Sensitivity |
High/Middle/Low 77dB/80dB/82dB three modes |
VOX auto mic time-out |
6~180 seconds |
Microphone stem length |
410mm(standard) 310mm/510mm optional |
Dimension (L×W×H) |
100mm×40mm×60mm |
Hole Dimension (L×W) |
124±4×33±2 table thickness ≥15mm |
Weight |
0.08Kg |
Working temperature |
0~45℃ |
Storage temperature |
-20~50℃ |
Projects
*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*
![]() |
![]() |
![]() |
University of Science and Technology of China |
Hall of operational meetings of the Academic Council
|
Ural Institute of state fire fighting service,Russia
|
The flush voting unit allows the delegate to register attendance and cast a vote for YES/ABST/NO, evaluation and election. Votes are counted automatically and the result is shown on display equipment such as large screen, projector/screen and white board. Results can be printed out or saved in CD.
Main Features
Basic Functions
-- Normal voting and direct voting
-- Single-choice and multiple-choice voting
-- First keypress and final keypress voting
◆ LED indicator will indicate working status of voting, election and evaulation
Technical Specifications
Mounting type |
flush mounting |
Powered |
by the central control unit |
Weight |
0.08Kg |
Dimensions |
100×40×66mm (W×D×H) |
Hole Dimensions |
124±4×33±2(L×W)(table thickness≥15mm) |
Working temperature |
0℃ to 45℃ |
Storage temperature |
-20℃ to 50℃ |
Projects
*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*
![]() |
![]() |
![]() |
University of Science and Technology of China |
Hall of operational meetings of the Academic Council
|
Ural Institute of state fire fighting service,Russia |
Handheld Voting Keypad BJ-K5600
Connecting the discussion unit via RJ-45 port, the handheld voting keypad allows the delegate to register attendance and cast a vote for YES/ABST/NO, evaluation and election. Votes are counted automatically and the result is shown on display equipment such as large screen, projector/screen and white board. Results can be printed out or saved in CD.
Main Features
◆ Designed for ease of system expansion
◆ Handheld unit offers higher level of convenience and privacy
◆ LED indicators to show working status for voting
◆ Voting and evaluation options are defined by system software
◆ 30000V ESD protection circuit
◆ Waterproof and dustproof design
Basic Functions
◆ Plug-and-play handheld voting keypad is connected to basic discussion unit by extended interface to realize voting, election and evaulation function
◆ Registration:support key press to register,LED indicator to indicate the registration status
◆ Voting: Yes/NO / Abstain. Vote count and result display are enabled automatically by PC
-- Normal voting and direct voting
-- Single-choice and multiple-choice voting
-- First keypress and final keypress voting
◆ Election: elect one or more out of multiple candidates, with 'competitive election', 'equal number election' and 'quick election'
◆ Evaluation (opinion polls): Best, Good, Fair, Poor, evaluation can be customized by the software
◆ LED indicator will indicate working status of voting, election and evaulation
Technical Specifications
Mounting type |
handheld |
Extended interface |
RJ45 |
Dimensions |
120×55×15mm(H×W×D) |
Weight |
0.1Kg(hand-held voting keypad) |
Working temperature |
0~45℃ |
Storage temperature |
-20~50℃ |
Projects
*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*
![]() |
![]() |
![]() |
University of Science and Technology of China |
Hall of operational meetings of the Academic Council
|
Ural Institute of state fire fighting service,Russia |
Central Control Unit TL-ZB4
Main Functions
•In compliance with IEC60914 international standard
•With full digital audio technology, built-in high-speed CPU and high-performance DSP digital audio processor, CD sound quality.
•Supports 48KHz audio sample rate, acoustic frequency response can up to 20Hz~20KHz.
•Black tempered glass panel design, simple and high-end design. All the function divisions are clearly layout and easy to operate.
•The sever comes with built-in OLED panel to display system status, active mic, speaking mode.
•Language supports Chinese/ English. Russia, Spanish can be customized.
•Navigation knob for more convenient operation and management
•4 route port to connect conference units, the system has auto-repair function, support hot plug- and-play.
•One central control unit is able to accommodate 60-70 microphones. By cascading extension units,
•the system can support upto 4096 conference units.
•Universal voltage power switch for wider usable range and sufficient power supply.
•Support USB auto recording: after the front panel is inserted U disk, audio recording can be set automatically or manually. The recording status can be displayed in real time.
•Supports automatic video tracking (SD and HD), with preset panoramic position. Built-in 4×1 SD
•video matrix, to support SD video tracking without adding more device
•Input port for external audio signal: for alarm audio, PA, and other audio systems, the conference units can output audio signals synchronously.
•Internal clock and calendar, it will be displayed on central control unit, conference units.
•Built-in auto-detection fo conference units; before conferences, self-test can be run for each conference units.
•TCP/IP PC communication between central control unit and PC, which can achieve control
•management, remote fault diagnosis and remote update.
Stand-alone Mode Functions:
•ID number writing: the conference system supports automatically or manually assign ID to the corresponding equipment.
•All or individual units' VOX sensitivity are adjustable (apply to 5600 series)
•LCD screen contrast of Unit is adjustable (apply to 4200 series)•Speaking mode: Operator, Auto, FIFO, VOX, request to speak (with software).
•VOX function: in VOX mode, the unit will be activated when user speaks; VOX sensitivity can be adjust by the server ( high, middle, low); microphone time-out is adjustable ( 6-180 seconds).
•1-4 delegate unit can be used simultaneously (except chairman unit); chairman/vice chairman unit
are not subject to active mic limit, it’s allowed to open at any time.
•The system can have multiple chairman units; delegate unit can be set as vice-chairman units. There are unlimited chairman and vice-chairman units.
Extended functions under PC and software control
•Register function and real-time participants statistics.
•Centralized conference management, operator can allow or reject delegate request to talk.
•Speaking time limit can be preset for conference units; After the speaking time is up, the conference unit will be off.
•Conference audio recording and video recording(need audio video capture card)
•Delegate unit can be set to be vice-chairman units by software; vice-chairman unit is not subject to active mic limit.
•Support management software dual-system hot backup function; One control computer can be set
as backup and connect to the system; if the current computer has faults, the backup computer can be automatically hosted to ensure the smooth and continuous meeting.
•Conference management software can be customized.
Based on functions of Central Control Unit TL-Z4, Central Control Unit TL-ZB4 has functions below:
Extended functions under PC and software control
- Voting: Yes, No, Abstain . Vote counting and result display are enabled automatically by PC
- Single-choice and multiple-choice voting
- First key-press and final key-press voting
- Election: elect one or more out of N candidates, with 'competitive election', 'equal number election' and 'quick election’
- 4-key evaluation: Good, Fair, Poor, Abstain.
- Utilize multi-level error correction and data encryption technique to ensure information security.
- Customized voting options and voting methods, support customized language mode or display screen.
Max System Capacity | 4096 |
Standard Capacity | 60~70(different from various models) |
Acoustic Frequency Response | 20Hz~20KHz |
SNR | >96dBA |
Channel Isolation | >85dB |
Dynamic Range | >94dB |
THD | <0.05% |
Power | AC100~240V,50/60Hz |
Audio Port | 1 balanced (XLR) |
2 unbalanced (RCA) | |
Max Audio Output | LINE OUT :+20 dBu unbalanced |
BLANCE OUT :+20 dBu balanced | |
Output Impedance | >1KΩ |
External Audio Input | 0.775V (PHOENIX terminal) |
Central Control Method | RS-232 |
PC Connection Method | TCP/IP |
Camera Control Method | RS-485 |
Max Power Consumption | 300W |
Terminal Connection Port | 8-pin×4 |
13-pin×4 (for TC-Z4,TC-ZB4 only) | |
Channel selection | 6 (for TC-Z4,TC-ZB4 only) |
Display Screen | OLED (61mm×37mm) |
Audio recording port | USB (USB:FAT32) |
Audio recording File Size | 0.8M/m |
Active Delegate | 1/2/3/4 (not including chairman unit) |
VOX sensitivity | H/M/L (76dB/80dB/82dB) |
Support Camera Number | 4 SD cameras (built-in SD matrix), MAX 8 cameras with extended matrix |
Video Input Port | RCA×4 (1Vp-p 75Ω) |
Video Output Port | RCA×2 (1Vp-p 75Ω) |
Camera Tracking Protocol | PELCO-P/PELCO-D/VISCA |
Operating Temperature | -0~45℃ |
Storage Temperature | -20~50℃ |
Dimensions (L*W*H) | 485mm×350mm×90mm |
Installation | Desktop or 19" rack mounting |
Weight | 7.6Kg |
Projects
*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*
![]() |
![]() |
![]() |
University of Science and Technology of China |
Hall of operational meetings of the Academic Council
|
Ural Institute of state fire fighting service,Russia |
Loudspeaker SPK-10
The flush loudspeaker delivers natural and clear sound. When it is used with the flush discussion unit, any smaller conference can be held without external sound equipment.
Main Features
◆ Simple and stylish design
Basic Functions
◆ Loudspeaker volume level can be adjusted individually, or centrally by CCU
◆ High-definition audio processing
◆ 30000V ESD protection circuit MIC is turned on
◆ Human-friendly inclination angle, make its performance better
Technical Specifications
Mounting type | flush mounting |
Powered | 2W/8Ω |
Frequency response | 200Hz~16KHz |
Sensitivity | 89dB |
Powered | by the central control unit |
Dimension(W×D×H) | 100mm×40mm×70mm |
Hole Dimension(L×W) | 124±4×33±2(table thickness≥15mm) |
Weight | 0.09Kg |
Working temperature | 0~45℃ |
Storage temperature | -20~50℃ |
Projects
*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*
![]() |
![]() |
![]() |
University of Science and Technology of China |
Hall of operational meetings of the Academic Council
|
Ural Institute of state fire fighting service,Russia |
The CON-5600 connector is designed to connect control units to function modules including discussion unit, channel selection unit, flush voting unit and/or loudspeaker for power supply and communication signals.
Technical Specifications
Working temperature |
0~45℃ |
Storage temperature |
-20 ~ 50℃ |
Dimensions (WxDxH) |
167x160x40mm |
Net weight |
1083 g |
Projects
*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*
![]() |
![]() |
![]() |
University of Science and Technology of China |
Hall of operational meetings of the Academic Council
|
Ural Institute of state fire fighting service,Russia |
Extension Unit ZJ-KR
Functions
•With full digital audio technology, built-in high-speed CPU and high-performance DSP digital audio processor.
•Black tempered glass panel design, simple and high-end design. All the function divisions are clearly layout and easy to operate.
•Three routes 8-pin ports to connect conferenc units, another two route 8-pin port for system cascading.
•Three routes 13-pin ports to connect conferenc units, another two route 13-pin port for system cascading.
•Automatic restoration function: support hot plug and play.
•One central control unit is able to accommodate 60-70 units. By cascading extension units, the system can support upto 4096 conference units.
•Universal voltage power switch for wider usable range and sufficient power supply.
Technical Specifications
Max System Capacity | 4096 |
Standard Capacity | 60~70(different from various models) |
Power | AC100~240V,50/60Hz |
MAX Power | 300W |
Terminal Connection Port | 8-pin ×5,13-pin×5 |
Operating Temperature | 0~45°C |
Storage Temperature | -20~50°C |
Dimensions (L*W*H) | 485mm×350mm×90mm |
Installation | Desktop or 19" rack mounting |
Weight | 7.6Kg |
Projects
*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*
![]() |
![]() |
![]() |
University of Science and Technology of China |
Hall of operational meetings of the Academic Council
|
Ural Institute of state fire fighting service,Russia |