Wired Flush-mounting Basic Discussion System TL-5600(基础讨论终端)
TL-5600 Digital Conference System
System Features
Flexible module-based solution
Five function modules can be stand-alone installed or easily combined to meet the exact customer needs, offering a versatile conference solution.
Smart voice activation mode
The system can be operated under VOX mode so that the microphone is automatically turned on when the delegate speaks. VOX sensitivity can be set to H/M/L to suit conference environment. Voice activation mode enables hands-free operation with no need to push the microphone button.
Future-proof system expansion
TL-5600 system offers perfect solution to upgrade the system and extend more features when necessary. Expansion port is designed to easily connect plug-and-play handheld module.
Proudct Features
Projects
*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~
![]() |
![]() |
![]() |
Iraq Medical Center | Olsztyn University, Poland | Plenary Hall, City ALICANTE |
Discussion Unit TL-VDQ5600/ TL-VXQ5600
Delegate discussion unit (TL-VDQ5600) allows the delegate to talk, request to talk, and register attendance. 1 to 4 delegate microphones can be active simultaneously. Built-in loudspeaker automatically mutes when the microphone is turned on. Chairman discussion unit (TL-VXQ5600) has the additional priority button to override all active delegate units to control the conference. Multiple chairman and vice-chairman discussion units can be used in one system, and can be active at any time regardless of preset delegate microphone limit.
Main Features
◆ Blue LED indicator for chairman or VIP
Basic Functions
Technical Specifications
Installation |
flush mounting |
Frequency response |
30Hz~20KHz |
Max SPL |
125dB (THD<3%) |
Dynamic range |
85dB |
Sensitivity |
-46dB±4dB |
THD |
THD<0.3% |
SNR |
≥95dB |
Power |
24V |
VOX Sensitivity |
High/Middle/Low 77dB/80dB/82dB three modes |
VOX auto mic time-out |
6~180 seconds |
Microphone stem length |
410mm(standard) 310mm/510mm optional |
Dimension (L×W×H) |
100mm×40mm×60mm |
Hole Dimension (L×W) |
124±4×33±2 table thickness ≥15mm |
Weight |
0.08Kg |
Working temperature |
0~45℃ |
Storage temperature |
-20~50℃ |
Projects
*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*
![]() |
![]() |
![]() |
University of Science and Technology of China |
Hall of operational meetings of the Academic Council
|
Ural Institute of state fire fighting service,Russia
|
Central Control Unit TL-Z4
Basic functions
◆ In compliance with IEC60914 international standard
◆ With full digital audio technology, built-in high-speed CPU and high-performance DSP digital audio processor, CD sound quality.
◆ Supports 48KHz audio sample rate, acoustic frequency response can up to 20Hz~20KHz.
◆ Black tempered glass panel design, simple and high-end design. All the function divisions are clearly layout and easy to operate.
◆ The sever comes with built-in OLED panel to display system status, active mic, speaking mode. Language supports Chinese/ English. Russia, Spanish can be customized.
◆ Navigation knob for more convenient operation and management
◆ 4 route port to connect conference units, the system has auto-repair function, support hot plugand- play.
◆ One central control unit is able to accommodate 60-70 microphones. By cascading extension units, the system can support upto 4096 conference units.
◆ Universal voltage power switch for wider usable range and sufficient power supply.
◆ Support USB auto recording: after the front panel is inserted U disk, audio recording can be set
automatically or manually. The recording status can be displayed in real time.
◆ Supports automatic video tracking (SD and HD), with preset panoramic position. Built-in 4×1 SD video matrix, to support SD video tracking without adding more device
◆ Input port for external audio signal: for alarm audio, PA, and other audio systems, the conference units can output audio signals synchronously.
◆ Internal clock and calendar, it will be displayed on central control unit, conference units.
◆ Built-in auto-detection fo conference units; before conferences, self-test can be run for each conference units.
◆ TCP/IP PC communication between central control unit and PC, which can achieve control management, remote fault diagnosis and remote update.
Stand-alone Mode Functions:
◆ ID number writing: the conference system supports automatically or manually assign ID to the
corresponding equipment.
◆ All or individual units' VOX sensitivity are adjustable (apply to 5600 series)
◆ LCD screen contrast of Unit is adjustable (apply to 4200 series)
◆ Speaking mode: Operator, Auto, FIFO, VOX, request to speak (with software).
◆ VOX function: in VOX mode, the unit will be activated when user speaks; VOX sensitivity can be adjust by the server ( high, middle, low); microphone time-out is adjustable ( 6-180 seconds).
◆ 1-4 delegate unit can be used simultaneously (except chairman unit); chairman/vice chairman unit are not subject to active mic limit, it’s allowed to open at any time.
◆ The system can have multiple chairman units; delegate unit can be set as vice-chairman units. There are unlimited chairman and vice-chairman units.
Extended functions under PC and software control
◆ Register function and real-time participants statistics.
◆ Centralized conference management, operator can allow or reject delegate request to talk.
◆ Speaking time limit can be preset for conference units; After the speaking time is up, the conferenceunit will be off.
◆ Conference audio recording and video recording(need audio video capture card)
◆ Delegate unit can be set to be vice-chairman units by software; vice-chairman unit is not subject toactive mic limit.
◆ Support management software dual-system hot backup function; One control computer can be setas backup and connect to the system; if the current computer has faults, the backup computer canbe automatically hosted to ensure the smooth and continuous meeting.
◆ Conference management software can be customized.
Technical Parameters
Max System Capacity | 4096 |
Standard Capacity | 60~70(different from various models) |
Acoustic Frequency Response | 20Hz~20KHz |
SNR | >96dBA |
Channel Isolation | >85dB |
Dynamic Range | >94dB |
THD | <0.05% |
Power | AC100~240V,50/60Hz |
Audio Port | 1 balanced (XLR); 2 unbalanced (RCA) |
Max Audio Output | LINE OUT :+20 dBu unbalanced BLANCE OUT :+20 dBu balanced |
Output Impedance | >1KΩ |
External Audio Input | 0.775V (PHOENIX terminal) |
Central Control Method | RS-232 |
PC Connection Method | TCP/IP |
Camera Control Method | RS-485 |
Max Power Consumption | 300W |
Terminal Connection Port | 8-pin×4 13-pin×4 (for TC-Z4,TC-ZB4 only) |
Channel selection | 6 (for TC-Z4,TC-ZB4 only) |
Display Screen | OLED (61mm×37mm) |
Audio recording port | USB (USB:FAT32) |
Audio recording File Size | 0.8M/m |
Active Delegate | 1/2/3/4 (not including chairman unit) |
VOX sensitivity | H/M/L (76dB/80dB/82dB) |
Support Camera Number | 4 SD cameras (built-in SD matrix), MAX 8 cameras with extended matrix |
Video Input Port | RCA×4 (1Vp-p 75Ω) |
Video Output Port | RCA×2 (1Vp-p 75Ω) |
Camera Tracking Protocol | PELCO-P/PELCO-D/VISCA |
Operating Temperature | -0~45℃ |
Storage Temperature | -20~50℃ |
Dimensions (L*W*H) | 485mm×350mm×90mm |
Installation | Desktop or 19" rack mounting |
Weight | 7.6Kg |
Loudspeaker SPK-10
The flush loudspeaker delivers natural and clear sound. When it is used with the flush discussion unit, any smaller conference can be held without external sound equipment.
Main Features
◆ Simple and stylish design
◆ High-definition audio processing
◆ 30000V ESD protection circuit MIC is turned on
Basic Functions
◆ Loudspeaker volume level can be adjusted individually, or centrally by CCU
◆ Human-friendly inclination angle, make its performance better
Technical Specifications
Mounting type |
flush mounting |
Powered |
2W/8Ω |
Frequency response |
200Hz~16KHz |
Sensitivity |
89dB |
Powered |
by the central control unit |
Dimension(W×D×H) |
100mm×40mm×70mm |
Hole Dimension(L×W) |
124±4×33±2(table thickness≥15mm) |
Weight |
0.09Kg |
Working temperature |
0~45℃ |
Storage temperature |
-20~50℃ |
Projects
*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*
![]() |
![]() |
![]() |
University of Science and Technology of China |
Hall of operational meetings of the Academic Council
|
Ural Institute of state fire fighting service,Russia
|
Connector CON-5600
The CON-5600 connector is designed to connect control units to function modules including discussion unit, channel selection unit, flush voting unit and/or loudspeaker for power supply and communication signals.
Technical Specifications
Working temperature |
0~45℃ |
Storage temperature |
-20 ~ 50℃ |
Dimensions (WxDxH) |
167x160x40mm |
Net weight |
1083 g |
Projects
*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*
![]() |
![]() |
![]() |
University of Science and Technology of China |
Hall of operational meetings of the Academic Council
|
Ural Institute of state fire fighting service,Russia
|
Extension Unit ZJ-KR
Functions
◆ With full digital audio technology, built-in high-speed CPU and high-performance DSP digital audio processor.
◆ Black tempered glass panel design, simple and high-end design. All the function divisions are clearly layout and easy to operate.
◆ Three routes 8-pin ports to connect conferenc units, another two route 8-pin port for system cascading.
◆ Three routes 13-pin ports to connect conferenc units, another two route 13-pin port for system cascading.
◆ Automatic restoration function: support hot plug and play.
◆ One central control unit is able to accommodate 60-70 units. By cascading extension units, the system can support upto 4096 conference units.
◆ Universal voltage power switch for wider usable range and sufficient power supply.
Technical Specifications
Max System Capacity | 4096 |
Standard Capacity | 60~70(different from various models) |
Power | AC100~240V,50/60Hz |
MAX Power | 300W |
Terminal Connection Port | 8-pin ×5,13-pin×5 |
Operating Temperature | 0~45°C |
Storage Temperature | -20~50°C |
Dimensions (L*W*H) | 485mm×350mm×90mm |
Installation | Desktop or 19" rack mounting |
Weight | 7.6Kg |
Projects
*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*~*
![]() |
![]() |
![]() |
University of Science and Technology of China |
Hall of operational meetings of the Academic Council
|
Ural Institute of state fire fighting service,Russia
|